Todo: Install Proxmox VE itself on top of an existing Debian system.
https://www.virtualizationhowto.com/2025/12/ultimate-home-lab-starter-stack-for-2026-key-recommendations https://www.geekom.co.uk/best-mini-pcs-for-homelab
1.1. Hardware
https://www.coolblue.nl/product/972816/lenovo-thinkcentre-neo-50q-gen-5-13b9007tmb.html Lenovo ThinkCentre neo 50q Gen 5 - 13B9007TMBA https://www.lenovo.com/nl/nl/p/desktops/thinkcentre/m-series-tiny/lenovo-thinkcentre-m90q-gen-5-(intel)-tiny-pc/len102c0054
https://www.virtualizationhowto.com/2026/02/this-made-my-mini-pc-home-lab-feel-enterprise-grade-intel-vpro-with-amt https://www.virtualizationhowto.com/2024/01/minisforum-ms-01-review-best-home-server-mini-pc-early-2024
Minisforum MS-01 MSI Cubi NUC 13MQ i e kunt Lenovo m920q, P330, m80q en m90q toevoegen. Al mijn Tinies hebben vPro en dat maakt het veel gemakkelijker om te beheren wanneer (tot nu toe één keer) de boel in de soep loopt en je niet thuis bent.
AI Mischa van den Burg ----------------------------------- -------------------------------------------- Dell OptiPlex Micro Geekom A5/BD790i X3D HP EliteDesk 800 G4/G5/G6 Mini HP EliteDesk 800 G2 Mini i5-6400T/16GB/240GB Lenovo ThinkCentre M720q/M920q Tiny Minisforum MS-01 Minisforum MS-A2 32GB/Noisy
2. General
-
See www.proxmox.com[^].
-
See https://computingforgeeks.com/how-to-install-proxmox-ve-on-debian-bullseye.
3. Installation
-
Set firmware to UEFI with Secure Boot off.
-
Boot from USB key.
-
Select Install Proxmox VE and press Enter.
-
Click I agree.
Target Harddisk: /dev/sda
-
Click Next.
-
Type
Thailandin the Country field.Country Thailand Time zone Asia/Bangkok Keyboard Layout U.S. English
-
Click Next.
-
Type the level 1 password in the Password field.
-
Type the level 1 password in the Confirm field.
-
Type
smru-it@shoklo-unit.comin the Email field. -
Click Next.
-
Type
tbhf-pve-mrm.smru.shoklo-unit.comin the Hostname field. -
Type
10.10.1.16in the IP Address field.Management Interface: eno1 - ##:##:##:##:##:## (e1000e) Hostname (FQDN): tbhf-pve-mrm.smru.shoklo-unit.com IP Address (CIDR): 10.10.1.16 / 24 Gateway: 10.10.1.170 DNS Server: 10.10.1.1
-
Click Next.
-
Uncheck Automatically reboot after successful installation.
Filesystem: ext4 Disk(s): /dev/sda Country Thailand Time zone Asia/Bangkok Keymap: en-us Email: smru-it@shoklo-unit.com Management Interface: eno1 Hostname: tbhf-pve-mrm IP CIDR: 10.10.1.16/24 Gateway: 10.10.1.170 DNS Server: 10.10.1.1
-
Click Install.
-
Click Reboot.
4. Usage
-
Browse to tbhf-pve-mrm.
User name: root Password: ******** Realm: Linux PAM standard authentication Language: English Save User name: -
-
Click Login.
-
Click OK in the No valid subscription message..
-
Log in as root on the tbhf-pve-mrm server.
-
Note: Errors logged in the /var/log/syslog file.
grep -Ei --color=always "bad |brok|cann|crit|deni|err:|erro|fail|igno|insu|leak|lost|miss|not |such|unab|warn" /var/log/syslog
kernel: [ 0.000000] secureboot: Secure boot could not be determined (mode 0) kernel: [ 0.010658] secureboot: Secure boot could not be determined (mode 0) systemd-udevd[429]: ethtool: autonegotiation is unset or enabled, the speed and duplex are not writable. systemd-udevd[431]: ethtool: autonegotiation is unset or enabled, the speed and duplex are not writable. udevadm[393]: systemd-udev-settle.service is deprecated. Please fix zfs-import-cache.service, zfs-import-scan.service not to pull it in. systemd[1]: Starting Import ZFS pools by device scanning... systemd[1]: Finished Import ZFS pools by device scanning. kernel: [ 0.149761] ACPI: [Firmware Bug]: BIOS _OSI(Linux) query ignored systemd[1]: Condition check resulted in getty on tty2-tty6 if dbus and logind are not available being skipped. kernel: [ 0.202073] acpi PNP0A08:00: _OSC: platform does not support [PCIeHotplug SHPCHotplug PME] kernel: [ 0.218858] pci_bus 0000:02: extended config space not accessible kernel: [ 0.280520] system 00:05: [mem 0xfed90000-0xfed93fff] could not be reserved kernel: [ 0.280523] system 00:05: [mem 0xfee00000-0xfeefffff] could not be reserved kernel: [ 0.280753] system 00:06: [io 0x1800-0x18fe] could not be reserved kernel: [ 0.280759] system 00:06: [mem 0xfe000000-0xfe01ffff] could not be reserved kernel: [ 0.305175] pcieport 0000:00:1c.0: DPC: error containment capabilities: Int Msg #0, RPExt+ PoisonedTLP+ SwTrigger+ RP PIO Log 4, DL_ActiveErr+ kernel: [ 0.582327] platform eisa.0: EISA: Cannot allocate resource for mainboard kernel: [ 0.582329] platform eisa.0: Cannot allocate resource for EISA slot 1 kernel: [ 0.582330] platform eisa.0: Cannot allocate resource for EISA slot 2 kernel: [ 0.582331] platform eisa.0: Cannot allocate resource for EISA slot 3 kernel: [ 0.582331] platform eisa.0: Cannot allocate resource for EISA slot 4 kernel: [ 0.582332] platform eisa.0: Cannot allocate resource for EISA slot 5 kernel: [ 0.582333] platform eisa.0: Cannot allocate resource for EISA slot 6 kernel: [ 0.582334] platform eisa.0: Cannot allocate resource for EISA slot 7 kernel: [ 0.582335] platform eisa.0: Cannot allocate resource for EISA slot 8 kernel: [ 1.024249] RAS: Correctable Errors collector initialized. kernel: [ 1.221868] wmi_bus wmi_bus-PNP0C14:04: WQBC data block query control method not found kernel: [ 3.313557] EXT4-fs (dm-1): re-mounted. Opts: errors=remount-ro. Quota mode: none. kernel: [ 3.881059] i915 0000:00:02.0: [drm] failed to retrieve link info, disabling eDP kernel: [ 5.436184] softdog: soft_reboot_cmd=<not set> soft_active_on_boot=0 smartd[639]: Configuration file /etc/smartd.conf was parsed, found DEVICESCAN, scanning devices smartd[639]: Device: /dev/sda [SAT], not found in smartd database. systemd-udevd[424]: ethtool: autonegotiation is unset or enabled, the speed and duplex are not writable. postfix/postfix-script[885]: warning: symlink leaves directory: /etc/postfix/./makedefs.out pvescheduler[969]: jobs: cfs-lock 'file-jobs_cfg' error: pve cluster filesystem not online. pvescheduler[968]: replication: cfs-lock 'file-replication_cfg' error: pve cluster filesystem not online. systemd[1485]: gpgconf: error running '/usr/lib/gnupg/scdaemon': probably not installed
5. Create VM
-
Select Server View.
-
Select Datacenter > delta-pve-frl > local (delta-pve-frl) > ISO images.
-
Click Upload.
-
Click Select File.
-
Select the W:\Images\Debian\Debian 11\debian-13.4.0-amd64-netinst.iso file.
-
Click Open.
-
Click Upload.
-
Close the Task viewer: Copy data window.
-
Click Creae VM.
Node: delta-pve-frl Resource Pool: VM ID: 100 Name: pve-debian Add to HA: +
-
Click Next.
-
Select ISO Image : | debian-13.4.0-amd64-netinst.iso.
-
Click Next.
-
Click Next.
-
Click Next.
-
Click Next.
-
Click Next.
-
Click Next.
-
Click Finish.
-
Select Datacenter > delta-pve-frl > 100 (pve-debian).
-
Click Start.
-
Select Console.
6. Configuration
7. VirtualBox
-
See https://pve.proxmox.com/wiki/Proxmox_VE_inside_VirtualBox.
-
Note: Make sure to disable all Hyper-V features in Windows Features. BACKSLASH3: OK
-
Note: Make sure to disable Virtual Machine Platform feature in Windows Features. BACKSLASH3: Enabled !!!
-
Note: Make sure to disable Windows Hypervisor Platform feature in Windows Features. BACKSLASH3: OK
-
Note: Make sure to disable Windows Sandbox feature in Windows Features. BACKSLASH3: Missing on Windows 11 Home
-
Note: Make sure to disable Windows Subsystem for Linux feature in Windows Features. BACKSLASH3: OK
-
Note: Make sure to disable Virtualization Based Security on Windows 11.
-
Note: Check with
bcdedit.exethat hypervisorlaunchtype is disabled on Windows 11. BACKSLASH3: Auto ! -
Note: Check with
bcdedit.exethat vmslaunchtype is disabled on Windows 11. BACKSLASH3: -
-
Boot the computer from the proxmox-ve_9.1-1.iso file.
-
Select Install Proxmox VE (Graphical) and press Enter.
-
Click I agree.
-
Click Next.
-
Type
Netherlandsfor the Country. -
Select Europe/Amsterdam for the Time zone.
-
Select U.S. English for the Keyboard layout.
-
Click Next.
-
Type the Level 1 password in the Password field.
-
Type the Level 1 password in the Confirm field.
-
Type
douwe@deltasoftware.frlfor the Email. -
Click Next.
Management Interface nic0 - 08:00:27:e0:8c:56 (e1000) Hostname (FQDN) delta-pve-frl.deltasoftware.frl IP Address (CIDR) 10.0.2.15 / 24 Gateway 10.0.2.2 DNS Server 62.45.70.103 + Pin network interface names -
Click Next.
-
Uncheck Automatically reboot after successful installation.
-
Click Install.
-
Remove the proxmox-ve_9.1-1.iso file from Devices > Optical Drives.
-
Click Reboot.
-
Set up Port Forwarding in VirtualBox.
HTTPS TCP 127.0.0.1 8006 10.0.2.15 8006
-
Browse to https://10.0.2.15:8006.
User name: root Password: ******** Realm: Linux PAM standard authentication Realm: Proxmox VE authentication server Language: English - English Save User name: -
-
Click Login.
You do not have a valid subscription for this server. Please visit www.proxmox.com to get a list of available options.
-
Click OK.
-
Select root@pam > Logout.
8. SSH
ss -a -4 | grep ssh
9. Console
-
Log in as root with the Level 1 password.